0
home

SHIMADZU ATOMIC ABSORPTION SPECTROPHOTOMETER FLAME MODEL NO. AA-7000F JAPAN

home
SHIMADZU ATOMIC ABSORPTION SPECTROPHOTOMETER FLAME MODEL NO. AA-7000F JAPAN
SHIMADZU ATOMIC ABSORPTION SPECTROPHOTOMETER FLAME MODEL NO. AA-7000F JAPAN
Price And Quantity
  • 1
  • Piece/Pieces
  • 5000 INR
Product Description

SHIMADZU ATOMIC ABSORPTION SPECTROPHOTOMETER FLAME MODEL NO. AA-7000F JAPAN

TECHNICAL SPECIFICATIONS :

OPTICS :

Wavelength Range : 185.0 to 900.0nm

Monochromator : Aberration-corrected Czer by-Turner mounting

Bandwidth : 0.2,0.7,1.3,2.0L nm (4-step automatic switching)

Detector : Photomultiplier tube

Optics : Optical double beam

Background correction

method : * BGC-SR (high-speed self-reversal method) (185.0 to 900.0nm)

*BGC-D2 (D2 lamp mehtiod)

(185.0 to 430.0 nm)

Number of HC Lamps : 6-lamp turret, 2 lamps simultaneously

lit (1 for measurement

1 warming up fornext

measurement)

Lamp mode : EMMISSION, NON-BGC, BGC-D2;

BGC-SR

DATA PROCESSING :

-----------------------------------------------

Software requirement : Microsoft Windows Vista Business / XP

Professional

Parameter setting : Wizard mehtod

Measurement mode : Flame continous method, flame micro

sampling method, furnace

emmission method

Concentration computation

Mode : * Calibration curve method(select

primary, secondary, tertiary)

*Standard addition method, simple

 

standard addition mehtod (primary

expression)

Repeat analysis : Up to 20 repetitions, Mean valve,

standard deviation (SD) and

Coeffeicient of variation (RSD)

display

Automatic exclusion of deviant

values by setting SD and %RSD

Baseline correction : Automatic correction of baseline drift by

offset correction in peak height/

peak area modes.

Signal processing

segment setting : Signal processing segments can be

changed in peak height/peak

area modes

Sensitivity corrections : Automatic calibration curve correction

function using sensitivity

monitoring

Analog output : 2 channels (atomic absorption/energy

signal, background signal)

output range : 5.0,2.0,1.25,0.625 Abs.

V (each settable in 4 stages)

Fixed at 1 VF.S. in EMISSION mode.

Tabular data processing : Final concentration calculations on

sampled volume, dilution rate,

fixed volume and factor inputs

Recall of parameters : Template functions available

Procedure/result display: MRT (measurement results Table)

worksheet

Report generation : Summary report

QA/QC : Select whether to continue or

discontinue measurements based on

results of evalauation or coefficient of

correction

* RSD, ICV, CCV,CCB, PB, LCS,

 

SPK, PDS and DUP

Re-analysis : * Select whether on not to be conduct

re-analysis

* Automatic dilution and re-analysis of

unknown samples via autosampler

(flame micro sampling method

furnance method)

Digital recording : *Management by login ID and password

Control user access authority by user

level

Log record, Audit trail, Electronic

signature

Power requirement : Choose from 100,120,220 or 230 VAC,

50/60 HZ

(Power is required separately for the

personal computer)

Dimensions &

weight : 700 W x 588 D x 714 mm; 72 kg

Ambient temperature/

humidity : 10 to 35 C, 20 to 80C, less than 70 ;

when temperature is higher than 30C)

FLAME :

  • Burner unit Type : Air-cooled pre-mix type

  • Burner head : Titanum 10 cm slot 15 cm titanium slot for

  • N2O-C2H2;

  • (flame is available as an option)

  • Nebulizer : PHr capillary; PTFE orifice; ceramic impact

  • bead

Trade Information
  • 5-10 piece Per Month
  • 6-8 Week
    Related Products
    Abbe Refractometer


    Send Inquiry
    Combustion crucible - high form


    Send Inquiry
    120l X 384 Square Well Micro Plate with SBS Footprint


    Send Inquiry
    RM 100 TOUCH GEL TIMER


    Send Inquiry
    right arrow
    left arrow
    Contact Us

    Kesarkunj, Room No. 9, 2nd Floor, Vasanji Lalji Road, Kandivali Station Road, Kandivali (West), Mumbai, Maharashtra, 400067, India
    Phone :+918037301692