SHIMADZU ATOMIC ABSORPTION SPECTROPHOTOMETER FLAME MODEL NO. AA-7000F JAPAN
TECHNICAL SPECIFICATIONS :
OPTICS :
Wavelength Range : 185.0 to 900.0nm
Monochromator : Aberration-corrected Czer by-Turner mounting
Bandwidth : 0.2,0.7,1.3,2.0L nm (4-step automatic switching)
Detector : Photomultiplier tube
Optics : Optical double beam
Background correction
method : * BGC-SR (high-speed self-reversal method) (185.0 to 900.0nm)
*BGC-D2 (D2 lamp mehtiod)
(185.0 to 430.0 nm)
Number of HC Lamps : 6-lamp turret, 2 lamps simultaneously
lit (1 for measurement
1 warming up fornext
measurement)
Lamp mode : EMMISSION, NON-BGC, BGC-D2;
BGC-SR
DATA PROCESSING :
-----------------------------------------------
Software requirement : Microsoft Windows Vista Business / XP
Professional
Parameter setting : Wizard mehtod
Measurement mode : Flame continous method, flame micro
sampling method, furnace
emmission method
Concentration computation
Mode : * Calibration curve method(select
primary, secondary, tertiary)
*Standard addition method, simple
standard addition mehtod (primary
expression)
Repeat analysis : Up to 20 repetitions, Mean valve,
standard deviation (SD) and
Coeffeicient of variation (RSD)
display
Automatic exclusion of deviant
values by setting SD and %RSD
Baseline correction : Automatic correction of baseline drift by
offset correction in peak height/
peak area modes.
Signal processing
segment setting : Signal processing segments can be
changed in peak height/peak
area modes
Sensitivity corrections : Automatic calibration curve correction
function using sensitivity
monitoring
Analog output : 2 channels (atomic absorption/energy
signal, background signal)
output range : 5.0,2.0,1.25,0.625 Abs.
V (each settable in 4 stages)
Fixed at 1 VF.S. in EMISSION mode.
Tabular data processing : Final concentration calculations on
sampled volume, dilution rate,
fixed volume and factor inputs
Recall of parameters : Template functions available
Procedure/result display: MRT (measurement results Table)
worksheet
Report generation : Summary report
QA/QC : Select whether to continue or
discontinue measurements based on
results of evalauation or coefficient of
correction
* RSD, ICV, CCV,CCB, PB, LCS,
SPK, PDS and DUP
Re-analysis : * Select whether on not to be conduct
re-analysis
* Automatic dilution and re-analysis of
unknown samples via autosampler
(flame micro sampling method
furnance method)
Digital recording : *Management by login ID and password
Control user access authority by user
level
Log record, Audit trail, Electronic
signature
Power requirement : Choose from 100,120,220 or 230 VAC,
50/60 HZ
(Power is required separately for the
personal computer)
Dimensions &
weight : 700 W x 588 D x 714 mm; 72 kg
Ambient temperature/
humidity : 10 to 35 C, 20 to 80C, less than 70 ;
when temperature is higher than 30C)
FLAME :
Burner unit Type : Air-cooled pre-mix type
Burner head : Titanum 10 cm slot 15 cm titanium slot for
N2O-C2H2;
(flame is available as an option)
Nebulizer : PHr capillary; PTFE orifice; ceramic impact
bead