UV SPECTROPHOTOMETER 1280

home
UV SPECTROPHOTOMETER 1280
UV SPECTROPHOTOMETER 1280
Price And Quantity
  • 1
  • Piece/Pieces
  • 5000 INR
Product Description

Specification:

Spectral bandwidth: 5 nm

Wavelength range: 190.0 to 1100.0 nm

Wavelength display: 0.1 nm increments

Wavelength setting: 0.1 nm increments

Wavelength accuracy: ±1.0 nm

Wavelength repeatability: ±0.3 nm

Wavelength slew rate: Approx. 6,000 nm/min Wavelength scanning

Speed: Approx. 9 nm/min to 1,600 nm/min

Light source switching: Select from the following three:

O Automatic switching linked to the wavelength theswitching

wavelength can be selected between 295 nm and 364 nm, in1 nm

increments. The recommended wavelength is 340 nm.

O Use the halogen (WI) lamp only, with no switching

O Use the deuterium (D2) lamp only, with no switching

------------------------------------------------------------

Stray light: 0.05 % or less (220.0 nm NaI, 340.0 nmNaNO2)

Photometric system: Monitor double beam optics

Photometric range: Absorbance: -0.3 to 3.0 AbsTransmittance:

0.0% to 200%

Recording range: Absorbance: -4.0 to 4.0 AbsTransmittance: -400%

to 400%

------------------------------------------------------------

Photometric accuracy: ±0.005 Abs at 1.0 Abs ±0.003 Abs at0.5 Abs

Using NIST 930D filter

Photometric repeatability: ±0.002 Abs at 1.0 Abs

------------------------------------------------------------

Baseline stability: ±0.001 Abs/h or less (700 nm, twohours after the

power is turned ON)

Baseline flatness: ±0.010 Abs or less (one hour after thepower is

turned ON, at 1,100nm to 200nm)

Noise level: P-P 0.002 Abs or less, RMS 0.0005 Abs orless

Baseline correction: Automatic correction via computermemory

------------------------------------------------------------

Light source: 20 W halogen lamp (2,000 hour operatinglife)

Deuterium lamp (socket type) Built-in light source autoposition

adjustment

Monochromator: Uses an aberration correcting concaveholographic

grating.

Detector: Siliconphotodiode

Sample compartment:

Internal dimensions: 110.0 (W) × 230.0 (D) × 105.0 (H) mm(Depth

of one part is 155.0 mm.) Attachment method: twofastening screws

------------------------------------------------------------

Display: 6-inch LCD (320×240 pixels) With LEDillumination with

contrast adjustment function

Output device: USB memory (optional) Data files saved inCSV

format or UV-1280 dedicated format.

Power requirements: 100 to 240 V, 50/60 Hz, 140 VA

Dimensions: W416 × D379 × H274 mm

Weight: 10 kg.

Environmental requirements: Temperature: 15 °C to 35 °C

Humidity:30 % to 80 % Humidity of 70 % or less at temperatures of 30 °C or higher
Trade Information
  • Mumbai
  • Cash Advance (CA), Cash in Advance (CID), Telegraphic Transfer (T/T)
  • 5-10 piece Per Month
  • 6-8 Week
  • All India
  • ISO CERTIFICATE 9001:2005
    Related Products
    Other Vacuum Manifold Components - Plate  19mm


    Send Inquiry
    4 TIP FILTER FOR PIPETTE TIPS


    Send Inquiry
    STERILITY TEST MANIFOLD SYSTEM 3,6 STATIONS


    Send Inquiry
    Tubular Impact Tester - BS / ASTM


    Send Inquiry
    Anion Standards


    Send Inquiry
    NAC CR - Clean Room Ovens to 250C


    Send Inquiry
    right arrow
    left arrow
    Contact Us

    Kesarkunj, Room No. 9, 2nd Floor, Vasanji Lalji Road, Kandivali Station Road, Kandivali (West), Mumbai, Maharashtra, 400067, India
    Phone :+918037301692